Water Reservoir Cover Removal
QF2300
1. Place the toggle switch in the OFF position, turn off
the water supply and disconnect electrical power to
the ice machine.
2. Remove water level probes.
3. Remove water float valve coil.
4. Depress coil and rotate 1/4 turn counterclockwise.
5. With coil wires attached, lift coil off enclosure tube.
6. Remove top cover from float reservoir.
QF2300 Shown
Float Valve Removal
1. Place the toggle switch in the OFF position, turn off
the water supply and disconnect electrical power to
the ice machine.
2. Disconnect water supply line at float valve quick
disconnect by depressing stainless steel lever.
3. Remove water float valve coil.
4. Depress coil and rotate 1/4 turn counterclockwise.
5. With coil wires attached, lift coil off enclosure tube.
6. QF0800/QC0700/QF2300 ONLY Rotate quarter turn
fasteners counterclockwise.
7. QF0800/QC0700 ONLY Remove cotter key and pin
from ice chute.
8. Remove top cover from float reservoir.
9. Lift float valve out of float reservoir.