Manitowoc Ice S Ice Maker User Manual


 
Installation Instructions Section 2
2-14 Part Number 80-1620-3
WATER SUPPLY AND DRAIN LINE SIZING/CONNECTIONS
Refer to “Ice Machine Dimensions” at the beginning of Section 2 for the exact locations of inlets and drains for the model you are working on.
Typical Water Supply Drain Installation
!
Caution
Plumbing must conform to state and local codes.
Location Water Temperature Water Pressure Ice Machine Fitting
Tubing Size Up to Ice
Machine Fitting
Ice Making
Water Inlet
35°F (1.6°C) Min.
90°F (32.2°C) Max.
20 psi (137.9 kPA) Min.
80 psi (551.5 kPA) Max.
3/8" Female Pipe
Thread
3/8" (.95 cm) minimum
inside diameter
Ice Making
Water Drain
--- ---
1/2" Female
Pipe Thread
1/2" (1.27 cm) minimum
inside diameter
Condenser
Water Inlet
40°F (4.4°C) Min.
90°F (32.2°C) Max.
20 psi (137.9 kPA) Min.
150 psi (1034.2 kPA) Max.
3/8" Female Pipe Thread
Condenser
Water Drain
--- ---
1/2" Female
Pipe Thread
1/2" (1.27 cm) minimum
inside diameter
Bin Drain --- ---
3/4" Female
Pipe Thread
3/4" (1.91 cm) minimum
inside diameter
SV3142
ELECTRICAL ENTRANCE
18” (46 CM) VENT TUBE
AIR GAP
1/2” (1.3 CM) MIN
DRAIN ID
1/2” DRAIN CONNECTION
PLASTIC FITTING ON OPPOSITE
SIDE DO NOT APPLY HEAT
OPEN, TRAPPED AND
VENTED DRAIN
DO NOT TRAP DRAIN LINE,
LEAVE AIR GAP BETWEEN
DRAIN TUBE AND DRAIN
3/8” FPT ICE MAKING WATER INLET FITTING,
PLASTIC FITTING ON OPPOSITE SIDE DO NOT
APPLY HEAT
1/2” FPT CONDENSER WATER DRAIN
(WATER COOLED UNITS ONLY)
3/8” FPT CONDENSER WATER INLET
(WATER COOLED UNITS ONLY
1/2” CPVC SOCKET AUXILLARY BASE
DRAIN