Maintenance Section 4
4-6 Part Number 80-1620-3
REMOVAL OF PARTS FOR CLEANING/SANITIZING
1. Turn off the electrical and water supply to the ice
machine (and dispenser when applicable).
2. Remove all ice from the bin.
3. Remove the water curtain and the components you
want to clean or sanitize. See the following pages for
removal procedures for these parts.
4. Soak the removed part(s) in a properly mixed
solution.
5. Use a soft-bristle brush or sponge (NOT a wire
brush) to carefully clean the parts.
6. Use the sanitizing solution and a sponge or cloth to
sanitize (wipe) the interior of the ice machine and
the entire inside of the bin/dispenser.
7. Thoroughly rinse all of the parts and surfaces with
clear water.
8. Install the removed parts.
NOTE: Incomplete rinsing of the ice thickness probe or
water level probe may leave a residue. This could cause
the ice machine to malfunction. For best results, brush or
wipe the probes off while rinsing it. Thoroughly dry the
probes before installing them.
9. Turn on the water and electrical supply.
!
Warning
Disconnect electric power to the ice machine (and
dispenser if applicable) at the electric switch box
before proceeding.
!
Warning
Wear rubber gloves and safety goggles (and/or face
shield) when handling Ice Machine Cleaner or
Sanitizer.
Solution Type Water Mixed With
Cleaner 1 gal. (4 l) 16 oz (500 ml) cleaner
Sanitizer 4 gal. (15 l) 3 oz (90 ml) sanitizer
!
Caution
Do not mix Cleaner and Sanitizer solutions together.
It is a violation of Federal law to use these solutions
in a manner inconsistent with their labeling.
!
Caution
Do not immerse the water pump motor in the
cleaning or sanitizing solution.