Marvel Industries 6CiM Refrigerator User Manual


 
Temperature
Control and Selection
The temperature control knob is located in the grille
below the door. There is a pointer on the grille at the
12:00 position to indi-
cate knob position.
The "OFF" position will
turn the refrigeration
system off. Positions 1
is the warmest setting
and setting 7 is the
coldest. Wait at least 2
hours between tem-
perature adjustments
to find a temperature
that suits you.
The refrigerator section temperature of the unit can be
adjusted using the adjusting slide located in the left side
and rear of the refrigeration section. Turn in the cold
direction indicted to make the refrigeration section cold-
er and the opposite to warm the refrigeration section.
Defrost
This units uses an electronic control system to control
both defrost and refrigeration functions. This feature
eliminates the inconvenience of manual defrosting of the
evaporator in normal conditions. If commodities or ice
accidentally clog the drip tray, the obstruction must be
removed for proper defrost performance. It is normal for
some water droplets to be left on the evaporator or drip
tray. These will refreeze and be removed in the next
defrost cycle.
Defrosting is factory set to run after the compressor has
run approximately 12 hours. For climates with high
humidity levels and/or repeated opening of the door, an
optional 6-hour compressor run time is already pro-
grammed into the control. A switch will have to be set at
the control for this change to take place (consult your
distributor or authorized service center).
A drip tray heater is located in the unit for proper
removal of condensation. The heater will remain on as
long as the unit is plugged in. The control knob will not
turn the heater off. Unplug or disconnect power to the
unit if you are planning to leave the unit off or unattend-
ed for extended periods of time.
Icemaker Operation
Make certain water pressure is at least 20 psi and
no more than 120 psi and is turned on.
The unit must be installed level for proper icemak-
er operation.
The shut off arm wire must be down in its lowest
position for the icemaker to operate.
Make certain there are no obstructions in the fan
inlet and outlet. The fan is located beside the ice-
maker at the top of the freezer section.
When the freezer section and icemaker unit has
sufficiently cooled, the icemaker will harvest ice
cubes automatically.
When the ice bucket is full, the icemaker will auto-
matically shut off.
You may manually stop the icemaker by raising
the shut-off arm to the locking position at the up
most position.
Important
When operation of the appliance is to be discontinued
for any length of time, the ice cube cavity in the icemak-
er should be emptied and dried. The water supply and
power supply should also be shut off and the ice bucket
should be emptied and cleaned.
If the ice is not used regularly, it will clump together with
time. For best ice results, discard ice in the bin as
required and allow the icemaker to make a new fresh
batch of ice.
2
C
O
L
D
E
R
Arm down, Icemaker will operate