Maytag 8101P407-60 Double Oven User Manual


 
-10-
CAUTION: This cooktop is not removable. Do not attempt
to remove this cooktop. Save the natural gas orifices
removed from the appliance for possible future conversion
to natural gas.
For All Burner Locations:
a. Remove the top grates and burner caps.
b. Remove the burner head by removing two screws.
(See figure 9). NOTE: Convert one burner at a time to
avoid incorrect installation.
c. IMPORTANT: Replace these two screws after
removing burner head. The screws will secure orifice
holder and avoid damage to electrode or tubing while
changing orifice.
d. Remove the four factory installed natural gas orifices
from the center of the orifice holders using a 7mm nut
driver (see figure 9). Remember to keep the original
natural gas orifices for later conversion to natural gas.
e. Replace the orifice in each of the four orifice holders
with the correct LP/propane gas orifice (see figure 10).
IMPORTANT: Make sure orifice is secured in nut driver
before attempting to r eplace orifice. Tighten each orifice
until snug. Use caution not to over tighten.
f. Remove screws when orifice change is complete, and
remount burner heads.
I
MPORTANT: Choke must be added to left front
orifice holder only, as shown in figure 9.
g. Replace the burner caps and grates using caution
when replacing each burner cap so that electrode is not
damaged.
Figure 9
Surface Burner Configuration
Figure 10
SURFACE BURNERS TO LP/PROPANE GAS
9.2K NO COLOR
5K BLUE
16K RED
9.2K NO COLOR
ART# 9215-163-0
1 BLUE ORIFICE
2 NO COLOR ORIFICES
1 RED ORIFICE
NATURAL GAS ORIFICE TO LP ORIFICE CONVERSION
FOR EACH TYPE OF BURNER
FRONTOFTOP
9,200 BTU NATURAL GAS
CONVERTS TO 9,100 BTU LP GAS
INSTALL ORIFICE (NO COLOR)
.90 MM FOR LP
5,000 BTU NATURAL GAS
CONVERTS TO 4,000 BTU LP GAS
INST ALL (BLUE) ORIFICE
.64 MM FOR LP
16,000 BTU NATURAL GAS
CONVERTS TO 14,000 BTU LP GAS
INSTALL (RED) ORIFICE
1.14 MM F OR LP
9,200 BTU NATURAL GAS
CONVERTS TO 9,100 BTU LP GAS
INSTALL ORIFICE (NO COLOR)
.90 MM FOR LP
ART# 9215-155-0
IMPORTANT: Choke must be added
to left front orifice holder only.