Maytag 8101P407-60 Double Oven User Manual


 
-6-
If conversion to LP Gas is required, convert regulator
before installation. Oven/broil and top burner
conversion can be made from front of range.
a. A GAS SHUT-OFF VALVE SHOULD BE PUT IN AN
ACCESSIBLE LOCATION IN THE SUPPLY LINE
AHEAD OF THE RANGE, FOR TURNING ON AND
TURNING OFF GAS SUPPLY. Range is to be
connected to house piping with flexible metal
connectors for gas appliances. CONNECTOR NUTS
MUST NOT BE CONNECTED DIRECTLY TO PIPE
THREADS. THE CONNECTORS MUST BE
INSTALLED WITH ADAPTORS PROVIDED WITH THE
CONNECTOR.
b. The house piping and/or range connector used to
connect the range to the main gas supply must be
clean, free of metal shavings, rust, dirt and liquids (oil
or water). Dirt, etc. in the supply lines can work its way
into the range manifold and in turn cause failure of the
gas valves or controls and clog burners and/or pilot
orifices.
CAUTION: DO NOT LIFT OR MOVE RANGE BY
GRASPING MAIN TOP, DOOR HANDLES, OR
BACKGUARD.
c. Turn off all pilots and main gas valve of other gas
appliances.
d. Turn off main gas valve at meter.
e. Before connecting range, apply pipe thread compound
approved for LPG to all threads.
f. Use only a flexible connector to connect range to gas
supply at appliance pressure regulator using adaptors
supplied with connector. Regulator supplied with range
has 1/2² NPT female connection.
NOTE: It is recommended to use a CSA certified
flexible connector no longer than 36² (91.4cm)witha
minimum BTU/HR rating of 88,200.
See serial plate for type of gas range has been
manufactured for, located on flip-up plate at rear of
upper left hand corner of backguard.
g. Turn on main gas valve at meter, and relight pilots at
other gas appliances.
h. Apply a non-corrosive leak detection fluid to all joints
and fittings in the gas connection between the supply
line shut-off valve and the range. Include gas fittings
and joints in the range if connections were disturbed
during installation. Check for leaks! Bubbles appearing
around fittings and connections will indicate a leak. If a
leak appears, turn off supply line gas shut-off valve,
tighten connections, turn on the supply line gas shut off
valve, and retest for leaks.
CAUTION: NEVER CHECK FOR LEAKS WITH A
FLAME.
WHEN LEAK CHECK IS COMPLETE, WIPE OFF ALL
RESIDUE.
FIGURE 4
ADAPTOR
FLEXIBLE CONNECTOR
SHUT-OFF VALVE
ADAPTOR
REGULATOR