2-27
SECTION 2
INSTALLATION
Outlet Pressure Tap
Low Flame
Bypass Orifice
3/4 Union
Pilot Line
Low Flame
Bypass Line
1/2 Nuts
Main Orifice
Governor Adjustment
Gas Converter
Inlet Pressure Tap
Insert Converter In this
Position for Pressure
Regulation
Insert Converter In this
Position for use with LP
Gas
Burner Blower
Air Adjustment
PlateBurner
1/2 Compression Nut
High Flame
Solenoid Valve
Combination
Gas Control
Valve
Figure 2-36
Burner/Piping Assembly
GAS TYPE AND PRESSURE LABEL
IT ...... II
2H3+
...................
Predisposto per gas metano .................................................... 20 mbar
GB .... II
2H3+
...................
Adjusted for natural gas ........................................................... 20 mbar
FR .... II
2E+3+
.................
Essaye au gaz naturel (E/L) ................................................ 20-25 mbar
DE .... II
2ELL3B/P
...........
Eingestellt auf Erdgas (E) ........................................................ 20 mbar
DE .... II
2ELL3B/P
...........
Eingestellt auf Erdgas (LL)....................................................... 20 mbar
ES .... II
2H3+
...................
Preparado para gas natural...................................................... 20 mbar
NL..... II
2L3B/P
................
Aangelegd op aardgas ............................................................. 25 mbar
BE .... I
2E+
.......................
Essaye au gaz naturel/aangelo op aardgas ........................ 20-25 mbar
GAS TYPE AND PRESSURE LABEL
IT ...... II
2H3+
...................
Predisposto per G.P.L.................................................... 28-30/37 mbar
GB .... II
2H3+
...................
Adjusted for L.P.G.......................................................... 28-30/37 mbar
FR .... II
2E+3+
.................
Essaye au gaz naturel liquide ........................................ 28-30/37 mbar
DE .... II
2ELL3B/P
...........
Eingestellt auf Flüssiggas ........................................................ 50 mbar
ES .... II
2H3+
...................
Preparado para gas liquido ............................................ 28-30/37 mbar
NL..... II
2L3B/P
................
Aangelegd op vloeibaar gas..................................................... 30 mbar
BE .... I
3+
.........................
Aangelegd op vloeibaar gas/essaye au gaz liquide ....... 28-30/37 mbar