23
EN
22
EN
13/
IF OPERATING ABNORMALITIES OCCUR
12/ CLEANING YOUR APPLIANCE
• Periodically
Every 3 or 4 months, in order to remove any deposits, run a special maintenance programme, with-
out any items in the machine, using a special dishwasher cleaning product.
Important :
Keep this product out of children’s reach.
• If not using your dishwasher for a prolonged period:
Clean your dishwasher completely and then unplug it from the electricity supply and close the water
tap. Protect your machine from potential frost.
Advice :
Do not use abrasive powders, metal sponges and alcohol-based or thinner-based products.
Use a cloth or a sponge.
If you are moving house, run a soaking programme first of all, in order to avoid any water escaping.
• BEFORE CALLING FOR SERVICE
Problem Possible Causes What to do?
The door falls heavily when
opened (integratable model)
- Door springs not tensioned
enough to compensate for the
weight of the panel.
- Tighten the two tensioning
screws accessible in the bot-
tom section above the front
feet.
The door does not stay horizontal
when open or returns too
quickly
(integratable model)
- Door springs tensioned too
much.
- No wooden panel.
- Loosen the two tensioning
screws accessible in the bot-
tom section above the front
feet.
- Fit a temporary wooden panel
on the appliance and adjust
the springs.
The door catches when closing - Appliance not stable
- Door not centred on the tub
- Adjust the feet.
- Re-centre by adjusting the
rear feet.
The upper basket does not stay
in the high position
- Poor manipulation (the basket
is being pulled upwards too
quickly)
- Act more progressively (see
instructions), one side and
then the other.
Small leak around or under the
appliance (move the appliance
to locate the leak)
- Leak from the tap.
- Leak from the appliance.
(Cf. table fault d07).
- Check that a seal is fitted and
retighten the nut.
- Close the water tap and call a
technician.
Small leak at the door
- Appliance not stable or not level
- Door not centred on the tub.
- Adjust the feet.
- Re-centre by adjusting the rear
feet.
• SUMMARY OF THE FAULTS
Flashing LED(s)
for models without a display
Flashing LED(s)
d01 : water supply fault (tap) d07 : overflow / anti-leak fault
d02 : draining fault
d08 : sprinkling distribution fault
d03 : heating fault d11 : pressure sensor fault
d04 : temperature fault
d12 : filling fault (water inlet
detection system)
d05 : faulty motor d13 : faulty heating
d06 : faulty motor
d14 : installation fault : (incorrect drainage
connection or inadequate flow rate and tap).
Tip:
If one of the above faults occurs and you need to call a repair man, remember to tell him
the message displayed (d01, d02..) as this information will help him.