Setting the water hardness
The hardness of the water used in the
coffee system must be determined and
programmed into the appliance. The
water hardness will determine how
frequently the unit must be descaled to
properly maintain the coffee system.
The machine monitors the volume of
water passing through it in conjunction
with the hardness of the water and will
indicate when descaling is necessary.
Your local water authority can inform
you of the hardness of your tap water or
you can measure the hardness yourself
using the enclosed test strip.
^
Dip the strip into your tap water for
one second, then shake off any
excess water.
The result will be evident after one
minute.
If your water hardness is greater
than 40 gr/gal (700 ppm), the water
must be mixed in equal parts with
non-carbonated mineral water to
prevent excessive lime scale build
up. Never use distilled water.
Program
setting
Water
Hardness
gr/gal ppm
Hardness 1 1 (soft) 0 - 3 0 - 130
Hardness 2 1 (soft) 4 - 7 130 - 250
Hardness 3 2 (medium) 7 - 14 250 - 380
Hardness 4 3 (hard)
4 (very hard)
14 - 21
over 21
over 380
To adjust or set the water hardness
SETTINGS F
K12345 L on
G
k
C
^ Turn the left jog shuttle to "Settings".
PROGRAMMING
F
Y
K n
I
IJZ
^ Turn the right jog shuttle to the
"Programming" symbol, press to
confirm.
WATER HARDNESS
n IA M
T
U N
A
^
Turn the right jog shuttle to the "Water
hardness" symbol, press to confirm.
WATER HARDNESS
+
very hard - 4 B
~
^
Turn the right jog shuttle to set the
water hardness.
A check marks the current setting.
^
Press the right jog shuttle to save the
setting.
The display now shows the main screen.
The "back" symbol A is selected.
^
Press the right jog shuttle to return to
the main display menu.