Miele DA 279-4 Alu EXT Ventilation Hood User Manual


 
Total connected load* .........270W
Fan motor* ................200W
Hob lighting .............3x20W
Glass edge feature lighting ....10W
Voltage ....................230V
Frequency ..................50Hz
Fuse rating GB .................3A
AUS, NZ:
Plug rating ...................10A
Test marks ..........Electrical safety
......................C-Tick Mark
Electrically suppressed
according to AS/NZS 1044
Electrical cable length .........1.5m
Weight
DA 279-4....................32kg
DA 279-4 EXT ................29kg
Fan performance*
Extraction power according to
EN 61591
Extraction system C 150 mm:
Level I ...................200m
3
/h
Level II...................300m
3
/h
Level III ..................400m
3
/h
Level IV Intensive Setting ....640m
3
/h
Extraction system C 125 mm:
Level I ...................180m
3
/h
Level II...................280m
3
/h
Level III ..................380m
3
/h
Level IV Intensive Setting ....580m
3
/h
Unrestricted...............690m
3
/h
Recirculation with charcoal filter:
Level I ...................150m
3
/h
Level II...................210m
3
/h
Level III ..................330m
3
/h
Level IV Intensive Setting ....490m
3
/h
Special accessory for recirculation
mode:
Conversion kit DUW 20
Miele charcoal filter DKF 12-1
* For EXT models the connected load
and extraction power will depend on
the type of external motor fitted.
EXT models:
Length of connection cable to external
motor.......................1.9m
Technical data
38