Miele FN 9752 i Freezer User Manual


 
This appliance must be built in,
otherwise it could tip up.
Location
This appliance should be installed in a
dry, well-ventilated room. It should not
be installed where it is exposed to
direct sunlight or directly adjacent to a
heat-producing appliance such as an
oven or a radiator. The room
temperature should not go above or
below the climate range for which the
appliance is designed. The higher the
ambient temperature of the room, the
more energy the appliance requires to
operate.
Important: tropical / humid
environments
During periods of high humidity,
some condensation may appear on
outside surfaces of cooling
appliances. This condensation will
disappear when humidity levels
drop. For prevention, it is advisable
to install the appliance with sufficient
ventilation in a dry and/or an
air-conditioned room.
Please ensure that doors are closing
and sealing properly.
Please ensure that the appliance is
installed in accordance with these
installation instructions and that the
handle is fitted correctly. Should you
require further assistance please
contact your Miele customer service
centre.
Climate range
This appliance is designed for use
within certain climate ranges (ambient
temperatures), and should not be used
outside this range. The climate range of
the appliance is stated on the data
plate inside the appliance.
Climate range Ambient room
temperature
SN
N
ST
T
+10 °C to +32 °C
+16 °C to +32 °C
+16 °C to +38 °C
+16 °C to +43 °C
Operating in a room which is too cold
will cause the cooling system to switch
off for too long, causing the internal
temperature in the appliance to rise
with the risk of food deteriorating and
going off.
Ventilation
Air at the back of the appliance gets
warm. The appliance housing unit must
be constructed to allow sufficient space
for ventilation.
Air is taken in through the plinth of the
furniture housing unit.
A ventilation gap of at least 38 mm
depth must be provided behind the
appliance for air to circulate.
The cross-sectional area of the
ventilation gaps and also the
cross-sectional area beneath the
ceiling needs to be at least 200 cm
2
to
ensure that warm air can be drawn
through without hindrance. Otherwise
the appliance has to work harder,
resulting in an increase in electricity
consumption.
Installation
33