Mitsubishi Electronics LGH-F-RX3-E Ventilation Hood User Manual


 
LGH-F-RX3-E (Feb. 2009)
LGH-F-RX3-E
Performance Certied
to ARI 1060 Standard
ERV-26
System Selection
ERV-22LGH-F-RX3-E
Lossnay operation when indoor unit is stopped
Available
Not available
Lossnay stopping when indoor unit is operating
Selecting Lossnay fan speed
When interlocked with indoor unit for compatibility with R22, R407C and R410A
High/Low
Ventilation mode
Filter maintenance indicator
Lossnay error indicator
Delayed operation - selectable times
Delayed operation - selectable times
External control operating mode selection
×
Number of indoor units for interlocked group setting with one Lossnay unit
16 units
Number of Lossnay units for interlocked group setting with one indoor unit
1 unit
Interlocked with external device
Start/Stop
Fan speed selection
Fixed to high
Ventilation mode switching
Fixed to automatic
Filter maintenance indicator ×
Lossnay error indicator ×
Delayed operation
External control operating mode selection
Lossnay unit
LGH-RX type
PZ52SF-E
M-NET transmission cable
Remote controller
Interlocked with Mr. Slim
®
(
Refer to page 118
)
When using A-control remote controller
Lossnay operation when indoor unit is stopped
Lossnay stopping when indoor unit is operating ×
×
woL/hgiHcsele tion deeps naf yanssoL
Other common items
Lossnay error indicator ×
Ventilation mode
Fixed to automatic
Filter maintenance indicator ×
External control operating mode selection ×
Number of indoor units for interlocked group setting with one Lossnay unit1 unit
Number of Lossnay units for interlocked group setting with one indoor unit1 unit
Mr. Slim-Lossnay
®
connecting cable
(
Enclosed accessory
)
Remote
controller
PAR-21MAA
Lossnay remote
controller
cannot be used.
Lossnay unit
LGH-RX type
Start/Stop
woL/hgiHselection deeps naF
Ventilation mode
Energy Recovery
By-pass/ Auto
Filter maintenance indicator
Lossnay error indicator
Delayed operation
External control operating mode selection
Number of Lossnay units
15 units
(
In the case of LGH-200RX type, count each unit as two for calcultion)
stinu 2 srellortnoc etomer fo rebmuN
Lossnay remote controller
(PZ41SLB-E)
EXT. signal source
for interlocking
to the Lossnay
Lossnay unit
LGH-RX type
EXT. signal source
for interlocking
to the Lossnay
Lossnay unit
LGH-RX type
Interlocked with CITY MULTI
®
Independent Lossnay
®
Unit
(not interlocked with CITY MULTI
®
or Mr. Slim
®
systems)
CITY MULTI
®
indoor unit
Mr.Slim (A-control)
indoor unit
*1
*
1 Ventilation mode (Energy Recovery, Bypass, Auto) selectable from Centralized Controller, but not selectable
from remote controller.