Moffat E32D5 Convection Oven User Manual


 
Installation
4
MODEL
SERIAL
xxxxxx
LOT yywwxxx
CHRISTCHURCH ( NEW ZEALAND )
REGULATIONS AND USED ONLY IN A WELL-VENTILATED SPACE. REFER TO THE
THIS APPLIANCE SHALL BE INSTALLED IN ACCORDANCE WITH CURRENT
THIS APPLIANCE MUST BE EARTHED / GROUNDED
MOFFAT LIMITED
INSTRUCTIONS BEFORE INSTALLING AND USING THIS APPLIANCE.
A @ V a.c.
V a.c. Hz kW
CODE
1P+N+E
E22M3
USE22M3
12.0 115
110-120 50-60 1.5
Installation Requirements
Unpacking
1. Remove all packaging and transit protection including
all protective plastic coating from the exterior stainless
steel panels.
2. Check the oven and supplied parts for damage. Report
any damage immediately to the carrier and distributor.
3. Check that the following parts have been supplied with
your oven:-
4 x Leg Adjustable.
Water Connection Elbow.
4. Report any deficiencies to the distributor who supplied
your oven.
5. Securely fit the 4 legs supplied with the oven.
6. Check that the available electrical supply is correct to
that shown on the Technical Data Plate located on the
front right hand side panel.
Refer to ‘Specifications’ section, ‘Oven
Specifications Tables’.
Location
1. Position the oven in its approximate working position.
2. The unit should be positioned so that the control panel
and oven shelves are easily reachable for loading and
unloading.
Clearances
To ensure correct ventilation for the motor and controls,
the following minimum installation clearances are to be
adhered to:-
Top 200 mm / 8”.
Rear 75 mm / 3”.
Left-hand side 75 mm / 3”.
Right-hand side 75 mm / 3”.
NOTE: Fixed installations require at least 500 mm -
20” clearance at the right hand side of oven for
service access.
Stand Mounted Oven
For ovens that are to be mounted to a stand, the oven feet
are used to level the oven on the stand. Refer to the
instructions supplied with separately ordered stands for
mounting details.
Important:
The vent located on the top of the oven must NOT be
obstructed.
Important:
Installation shall comply with local electrical, health and safety requirements.
It is most important that this oven is installed correctly and that oven operation is correct before use.
If you have any questions regarding the proper installation and / or operation of this oven, please contact your local
Turbofan distributor.
Oven
Serial Number
Current Draw
Oven
Model Number
Electrical Power
Rating
Technical Data Plate - Data and Location
(example only)
*******
*****
*******
6.5
220-240 V a.c.
50/60 Hz
28.0 A @ 230 V a.c.
Oven Vent Location