Moffat GSV 5050 W Range User Manual


 
18
INSTALLATION
Positioning
Remove all the packaging and install the
cooker in a dry, ventilated room not near
curtains, paper, alcohol, petrol etc. (See
figure).
The appliance must be set on a heatproof
floor.
This appliance is approved to class “1”
regarding overheating of surrounding
surfaces.
It is mandatory to keep 20mm distance to
the adjacent furniture.
L.P.G. cookers or ovens MUST NOT
be installed below ground level, i.e. in
a basement, or aboard any boat,
yacht or other vessel.
The back wall of the appliance is
provided with two spacers for
maintaining the correct distance to the
back wall.
Bend the spacers to 90
o
(see fig)
The cooking appliance must be fitted
with a stability chain firmly secured
to the wall (see fig)
20 mm
20 mm
550 mm
C
2
1
3
4
5
6
7
8
G
150 mm
660 mm
WARNING !!!
BEND THE TWO SPACERS
TO 90º
Stability
chain
Stability
hook
Chain to be
short as
practicabl
Firmly fix
chain to rear
of cooker