Monessen Hearth VFCS30DNV Oven User Manual


 
20 58D6002
PILOT
OFF
REMOTE CONTROL
FLAME APPEARANCE
CHECKING BURNER FLAME
In normal operation at full rate after 15 minutes, the following flame appearances should be observed:
Theleftandrightrearamesshouldbeyellowandextend1"-2"abovemiddlelogs.Theyellowamesshouldnot contact
thelogs.Thereshouldbeglowingembersonthefrontsurfaceofthemiddlelog.Note: The flames and embers will be
an opaque orange color during the burn off time.
Figure 19 - Correct Flame Appearance
OPERATING INSTRUCTIONS
Avoid any drafts that alter burner flame patterns. Do not allow fans to blow directly into the stove. Do not place
ablowerinsidetheburnareaofthestove.Ceilingfansmaycreatedraftsthatalteramepatterns.Sootingandimproper
burningwillresult.
Duringmanufacturing,fabricatingandshipping,variouscomponentsofthisappliancearetreatedwithcertainoils,lmsor
bondingagents.Thesechemicalsarenotharmful,butmayproduceannoyingsmokeandsmellsastheyareburnedoffduring
theinitialoperationoftheappliance,possiblycausingheadachesoreyeorlungirritation.This is a normal and temporary
occurrence.
Theinitialbreak-inoperationshouldlasttwotothreehourswiththeburneratthehighestsetting.Providemaximumventila-
tionbyopeningwindowsordoorstoallowodorstodissipate.Anyodorsremainingafterthisinitialbreak-inwillbeslight
and will disappear with continued use.
Middle Log
Middle Log