NOTE REGARDING VENTED PRODUCTS
Thisproductmustbeinstalledbyalicensedplumberorgastter
when installed within the Commonwealth of Massachusetts.
AnyresidencewithadirectventproductmusthaveaCOdetector
installed in the residence.
Installation of the replace or vented gas log in the State of
Massachusetts requires the damper to be permanently removed or
welded in the fully open position.
Inaddition, anaturally ventedgas logmay notbe installedin a
bedroom or bathroom in the State of Massachusetts.
Flexlineinstallationmustnotexceed36inchesandmusthavea
T shutoff valve.
NOTE REGARDING VENT FREE PRODUCTS
Thisproductmustbeinstalledbyalicensedplumberorgastter
when installed within the Commonwealth of Massachusetts.
Inaddition,ventfreeproductsmaynotbeinstalledinabedroomor
bathroomregardlessofsizeortypeintheStateofMassachusetts.
Flexlineinstallationmustnotexceed36inchesandmusthavea
T shutoff valve.
CARBON MONOXIDE DETECTOR REQUIREMENTS
(2)Revise 10.8.3 by adding the following additional
requirements:
(a)For all side wall horizontally vented gas fueled equipment
installedineverydwelling,buildingorstructureusedinwholeor
inpartforresidentialpurposes,includingthoseownedoroperated
by the Commonwealth and where the side wall exhaust vent
terminationislessthanseven(7)feetabovenishedgradeinthe
areaoftheventing,includingbutnotlimitedtodecksandporches,
thefollowingrequirementsshallbesatised:
1. Installation of carbon monoxide detectors. At the time of
installationofthesidewallhorizontalventedgasfueledequipment,
theinstallingplumberorgasttershallobservethatahardwired
carbon monoxide detectorwith analarm andbattery back-upis
installedontheoorlevelwherethegasequipmentistobeinstalled.
Inaddition,theinstallingplumberorgasttershallobservethata
batteryoperatedorhardwiredcarbonmonoxidedetectorwithan
alarmisinstalledoneachadditionallevelofthedwelling,building
orstructureservedbythesidewallhorizontalventedgasfueled
equipment. It shall be the responsibility of the property owner
to secure theservices ofqualied licensedprofessionals forthe
installationofhardwiredcarbonmonoxidedetectors
a.In the event that the side wall horizontally vented gas
fueledequipmentisinstalledinacrawlspaceoranattic,thehard
wiredcarbonmonoxidedetectorwithalarmandbatteryback-up
maybeinstalledonthenextadjacentoorlevel.
b. In the event that the requirements of this subdivision can
not be met at the time of completion of installation, the owner
shall have a period of thirty (30) days to comply with the above
requirements;provided,however,thatduringsaidthirty(30)day
period,abatteryoperatedcarbonmonoxidedetectorwithanalarm
shall be installed.
Massachusetts Residents Only — Please read and follow these special requirements
2. Approved Carbon Monoxide Detectors. Eachcarbonmonoxide
detector as required in accordance with the above provisions shall
comply with NFPA 720 and be ANSI/UL 2034 listed and IAS
certied.
3. Signage. A metal or plastic identication plate shall be
permanentlymountedtotheexteriorofthebuildingataminimum
height of eight (8) feet above grade directly in line with the
exhaust vent terminal for the horizontally vented gas fueled
heatingapplianceorequipment.Thesignshallread,inprintsize
nolessthanone-half(1/2)inchinsize,“GASVENTDIRECTLY
BELOW.KEEPCLEAROFALLOBSTRUCTIONS.”
4. Inspection. The state or local gas inspector of the side wall
horizontally vented gas fueled equipment shall not approve the
installationunless,uponinspection,theinspectorobservescarbon
monoxidedetectorsandsignageinstalledinaccordancewiththe
provisionsof248CMR5.08(2)(a)1through4.
(b) Exemptions: The following equipment is exempt from 248
CMR5.08(2)(a)1through4:
1. The equipment listed in Chapter10 entitled "Equipment Not
RequiredToBeVented"inthemostcurrenteditionofNFPA54as
adoptedbytheBoard;and
2. Product Approved side wall horizontally vented gas fueled
equipment installed in a room or structure separate from the
dwelling, building or structure used in whole or in part for
residential purposes.
(c) Manufacturer requirements Gas Equipment Venting
System Provided. When the manufacturer of Product Approved
side wall horizontally vented gas equipment provides a venting
systemdesignorventingsystemcomponentswiththeequipment,
the instructions provided by the manufacturer for installation of
theequipmentandtheventingsystemshallinclude:
1.Detailedinstructionsfortheinstallationoftheventingsystem
designortheventingsystemcomponents;and
2.Acompletepartslistfortheventingsystemdesignorventing
system.
(d) Manufacturer requirements Gas Equipment Venting
System Not Provided. When the manufacturer of a Product
Approved side wall horizontally vented gas fueled equipment
doesnotprovidethepartsforventingtheuegases,butidenties
“special venting systems,” the following requirements shall be
satisedbythemanufacturer:
1.The referenced"special venting system"instructions shall be
included with the appliance or equipment installation instructions;
and
2.The“specialventingsystems”shallbeProductApprovedbythe
Board,andtheinstructionsforthatsystemshallincludeapartslist
and detailed installation instructions.
(e) A copy of all installation instructions for all Product Approved
side wall horizontally vented gas fueled equipment, all venting
instructions, all parts lists for venting instructions, and/or all
ventingdesign