Moyer Diebel MD-66 Dishwasher User Manual


 
25
Operation
Control Panel Operation
The final rinse pressure gauge is located behind the control panel. The top-mounted control panel
contains the Power ON/OFF switch, start push button, stop push button, and the water temperature
gauges for the wash tank and the final rinse. The function of these controls are:
A Final Rinse Pressure Gauge - Indicates the flowing water pressure during the final rinse.
Proper reading is 20-22 PSI.
B Power Switch - Turns power on and off to the dishwasher. The machine wills
automatically when the power is turned on.
C Cycle Light - Indicates when the dishwasher is ready for automatic operation.
D Start Push button -
Pushing the Start push button sets the machine for automatic
operation. The conveyor and pumps start when a dish rack is
inserted into the machine.
E Stop Push button - Pushing the Stop push button stops the conveyor and pumps.
F Temperature Gauges - Temperature gauges indicate the water temperature in the wash
tank and the final rinse water temperature during the final rinse.
START
POWER
ON
OFF
STOP
Final Rinse
Pressure
WINSTON-SALEM,NC
CHAMPION INDUSTRIES, INC.
10
0
30
20
PSI
60
50
40
20-22 PSI
Wash
Temperature
Final Rinse
Temperature
0
20
40
60
80
100
120
140
160
180
200
220
100
80
60
40
20
0
20
40
60
80
100
120
140
160
180
200
220
100
80
60
40
20
160°F/71°C
180-195°F
82-91°C
A
B
C
E
F
D
Model MD-44 Shown