Napoleon Grills V 600 Oven User Manual


 
5
www.napoleongrills.com
Leak Tesng Instrucons
WARNING! A leak test must be performed annually and each me a cylinder is hooked up or if a part
of the gas system is replaced.
WARNING! Never use an open ame to check for gas leaks. Be certain no sparks or open ames are
in the area while you check for leaks. Sparks or open ames will result in a re or explosion, damage to
property, serious bodily injury, or death.
Leak tesng: This must be done before inial use, annually, and whenever any gas components are replaced
or serviced. Do not smoke while performing this test, and remove all sources of ignion. See Leak Tesng
Diagram for areas to check. Turn all burner controls to the o posion. Turn gas supply valve on.
Brush a half-and-half soluon of liquid soap and water onto all joints and connecons of the regulator, hose,
manifolds and valves.
Bubbles will indicate a gas leak. Either ghten the loose joint or have the part replaced with one recommend-
ed by the Napoleon Customer Care department and have the grill inspected by a cered gas installer.
If the leak cannot be stopped, immediately shut o the gas supply, disconnect it, and have the grill inspected
by a cered gas installer or dealer. Do not use the grill unl the leak has been corrected.
Propane Cylinder Installaon: Pull out the tank drawer (do not disengage slides). Set cylinder inside tank ring.
Natural Gas Hook-Up: These connecons must be made by a licensed gas installer. This natural gas grill is sup-
plied with a 12 foot. (3.6 meter) supply hose and quick disconnect designed for natural gas and cered for
outdoor use. The gas grill is designed to operate at an inlet pressure of 4.5 in. water column. Piping and valves
upstream of the quick disconnect are not supplied. The installaon must comply with CAN B149.1 Natural Gas
and Propane installaon code in Canada, or to the Naonal Fuel Gas Code, ANSI Z223.1 in the United States.
The gas supply pipe must be suciently sized to supply the BTU/h specied on the rang plate, based on the
length of the piping run.
The quick disconnect must not be installed in an upward direcon and a readily accessible manual shut-o
valve must be installed upstream of, and as close to, the quick disconnect as is feasible. The ared end of the
hose must be connected to the unit as illustrated in the Natural Gas Hose Aachment diagram. Leak test all
joints prior to using the gas grill.
WARNING! For your safety, conversion kits are not available. It is manufactured to exact specica-
ons. Any aempt to convert your grill will void your warranty. Failure to follow these instrucons could
result in property damage, personal injury or death.
WARNING! A leak test must be performed annually and each me a cylinder is hooked up or if a part
of the gas system is replaced.