Parkinson Cowan CSIM 509 Range User Manual


 
17
Technical Data
Appliance Class 2 sub class 1 and Class 1
Appliance category
: II 2H3+
Appliance gas supply: Natural Gas G20 20mbar
Hob
Rear left burner (semi-rapid) 2,000 W
Front left burner (ultra-rapid) 3,500 W
Rear right burner (semi-rapid) 2,000 W
Front right burner (auxiliary) 1,000 W
Oven
Top heating element 1,045 W
Bottom heating element 1,250 W
Grill Element 1,880 W
Convection heating element 2,090 W
Convection fan 30 W
Oven light 15 W
Total rating 2,315 W
Supply voltage (50 Hz) 230-240 V
Dimensions
Height 900 mm
Depth 600 mm
Width 497 mm
Oven Capacity 1.7 Cu. ft
Oven light 15 W
Supply voltage (50 Hz) 230-240 V
Instructions for the Installer
BURNER ULTRA-RAPID SEMI-RAPID AUXILIARY
(large) (medium) (small)
POSITION MAX MIN MAX MIN MAX MIN
NOMINAL THERMAL
POWER kW 3.5 1.2 2.0 0.45 1.0 0.33
NOMINAL FLOW
RATE m
3
/h 0.333 0.114 0.190 0.043 0.095 0.031
NOZZLE REFERENCE 136 Adjust. 96 Adjust. 70 Adjust.
NOMINAL THERMAL
POWER kW 3.5 1.2 2.0 0.45 1.0 0.33
NOMINAL FLOW
RATE g/h 252 86.5 144 32 72 24
NOZZLE REFERENCE 93 56 71 32 50 28
NATURAL GAS
20 mbar
TYPE OF
GAS
CHARACTERISTICS
LPG GAS
28-30/37 mbar
1/100 mm
1/100 mm
VALUE = 49.92 MJ/Kg
VALUE = 37.78 MJ/m
3
Ws - 50.7 MJ/ m
3