TROUBLESHOOTING
If the unit appears to be malfunctioning, read through
the OPERATION section of this manual rst. If the problem
persists, check this troubleshooting section to see if you
can refer to the cause and remedy of the problem and
resolve it without a service call.
DANGER
Never attempt to repair or perform maintenance on
the unit until the main electrical power to the unit has
been disconnected!
Problem Cause Solution
No interior light Bulb is loose Tighten bulb
Bulb is burnt out Replace bulb
LED board is inoperable Contact Perlick Technical Service at
800-558-5592
Light stays on when door switch is closed Manual switch is on Turn manual switch o
Door is not making contact with the door
switch
Makre sure the door closes tightly
Noisy operation Soft sounds from compressor, fan motor and
valves heard
Normal operation
“Crackling” sound during defrost Normal operation
LED Controller display is ashing ”P1”* Thermostat probe has failed Contact Perlick Technical Service at
800-558-5592
LED Controller display is ashing “P2”* Evaporator probe has failed Contact Perlick Technical Service at
800-558-5592
LED Controller display is ashing “HA”* Internal compartment has exceeded the high
temperature alarm preset value for over 30
minutes.
Make sure the door is completely closed.
Check the door gasket seal. Replace if
necessary.
Check the condenser and clean it if
necessary.
Make sure the louvered plate is
unobstructed. If surrounding ambient
temperature has recently changed
dramatically, the compartment may be
aected.
Make sure the interior light is o.
Warm product was recently placed in the
cabinet. Wait 24 hours for the product to
chill and then recheck the temperature.
LED Controller display is ashing “LA”* Internal compartment has exceeded the low
temperature alarm preset value for over 30
minutes.
Make sure the door is completely closed.
Check the door gasket seal. Replace if
necessary.
If the surrounding ambient temperature
has recently changed dramatically, the
compartment temperature may be
aected.
Unit is not running No power is going to the unit. Home circuit breaker was tripped. Reset
the circuit breaker.
ON/OFF keypad is turned o. Turn it on.
If it is a Dual-Zone model, check the Dual-
Zone power switch (see page 4).
Condenser is dirty. Clean the condenser
* Applies to Signature Series models only