Pitco Frialator 26 Fryer User Manual


 
1-5
1.4.2.1 Fuel Types - Each fryer is equipped to work with one type of fuel. The type of fuel with
which the appliance is intended to operate is stamped on the data plate attached to the inside of the
door.
WARNING
DO NOT use an open flame to check for gas leaks!
1.4.2.2
Fuel Supply Line Leak and Pressure Testing - The fuel supply system must be tested
before the fryer is used. If the fuel line is going to be tested at a pressure greater than (>)1/2 PSIG
(3.45 kPa), make sure that the fryer is disconnected from the fuel line. If the fuel line is to be tested
at a pressure equal to or less than (
<) 1/2 PSIG (3.45 kPa), the fryer can be connected but the unit's
gas valve must be shut. Test all gas line connections for leaks with a solution of soap and water when
pressure is applied.
1.4.2.3 Gas Line Connection - Connect the fryer to the gas supply line with a connector that
complies with the Standard for Connectors for Movable Gas Appliances (ANSI Z21.69 or CAN/
CGA-6.16).
NOTICE
NEVER use an adaptor to make a smaller gas supply line fit the cooker
connection. This may not allow proper gas flow for optimum burner
operation, resulting in poor cooker performance. NEVER supply the cooker
with any fuel other than the type indicated on the data plate. Using the
incorrect gas type will cause improper operation.