Pitco Frialator Electric Fryer Fryer User Manual


 
L20-246 Rev 0 (12/01)
Allow all of the shortening to return to the tank.
Bubbles will be produced in the vat when all the
shortening has been returned. This means that
the return lines have been cleared.
· Close the RED Return Valve, by pushing upward
on the Red Return Valve Handle. This will turn
the pump off.
· Press the key and the Display will show
“OFF”.
· Allow the Drain and Return lines to drain for at
least 5 minutes before removing filter pan to re-
duce dripping.
Your machine is now ready to use.
ENGLISH
4
· Place the Paper Support Screen in the bottom of the
pan.
· Place filter Paper or Pad over screen making sure
that there is an equal amount of excess paper on
each side.
· Place the Retaining Frame on the paper or pad
making sure that all edges are being pressed down
evenly.
· Slide filter drawer back under fryer making sure
that the oil return pipe locates into its mating
connection.
CAUTION:
Be careful when using the clean out rod.
Damage to the drain valve may result.
WARNING:
Hot shortening can cause severe injury.
Take care when filtering or disposing of
hot shortening. Protective gear such as
gloves, apron, face shield and sleeves
should be worn.