4 Other Displays:
Open probe detection is standard on all Pitco
controls. If probe is detected open, normal
heating and cooking activities are suspended.
This display warns operators that the vat
temperature has exceeded set temperature by
+20°F (+11°C), or an absolute maximum of
240°F (156°C). This display does not show the
status of the mechanical high limit switch.
This message indicates that the drain valve has
been opened. The vat is assumed to be empty
by the controller. Normal heat control activities
are suspended. To restore to normal operation,
close the drain valve. Display will show [TURN
OFF].
Turn controller off, and refill the vat. Continue
with normal operations at section 1.
This message indicates that the heating system
failed to respond. Typically, the high
temperature limit switch has tripped and is in
need of resetting. On gas fired appliances, this
message will display if the pilot fails to light or is
detected marginal by the ignition module.
This message indicates a shorted probe. If probe
is detected as a short circuit, normal heating and
cooking activities are suspended.
This message appears when the tank fails to fill
within a set period of time. Check that the water
supply line is turned ON. To restore to normal
operation, turn the control OFF then ON again.
While the tank is (re)filling, heat is disabled.