Pitco Frialator L20-316 Range User Manual


 
Solstice I12 Cooking Computer Service
Part # 60153301
L20-316 Rev 0
8
2.3 Set the Food Safe temperature for this key:
A temperature value entered here defines the food safe temperature for this product key. Entry
must also be less than Set temperature. When the vat temperature goes below this
temperature, the cook timer halts. When the temperature is restored, the cook timer resumes.
A zero value will disable this feature. The factory default setting is 0°F, or inactive.
When display returns to [SELECT] [TIME]. Repeat steps from section 2.2.1 to make changes
to any other product keys or continue.
2.4 To Exit Level 1 programming:
Display shows [SELECT] [PRODUCT].
Press the key.
Display shows [PROGRAM]. Continue to section 3 to change options, or, exit here in the next step.
To exit Level 1 programming, press the key again.
Displays will show [HEATING],or [READY].
3 To Enter Programming Level 2 (for the Store Manager):
The display must show [PROGRAM] from section 2 to change these options. When the location key
is pressed, the display will show [SELECT] [OPTIONS]. Indicator lights above location keys will
illuminate to represent options that may be changed. Each option listed below uses the location key
to toggle or scroll through available choices in the display. When the correct value is displayed,
press the key to save choice. The display will again return to [PROGRAM] for another option
selection.
3.1 Fahrenheit or Celsius Display:
The Controller will display temperatures in the Fahrenheit or Celsius scales. The default scale is °F.
With display showing [PROGRAM], press the location key .
Display shows [SELECT] [OPTIONS].
Press location key 1, display shows [DEGREE n] [F OR C], where “n” is the current setting.
Display shows [SAFE ttt°F] [SHRIMP 9]
Enter
enter/change SAFE temp. 0°F= off.
Press [Clock]
Display shows
[SELECT] [TIME]
continue with other keys
Press
[P] to exit.
or exit
Display shows
[PROGRAM] [<blank>]
Enter the Food Safe
Temperature for this product
key
Set Food
Safe
Temperature
Exit