Castile & Santa Fe CE Pellet Stove
7068-112
We strongly recommend a minimum of
1.5m vertical, however above the eave is
preferred.
Bothinstallationsareapproved formobilehome
installations.Mustuse76mmto102mm“L”or“PL”
ListedpelletventingorListeddoublewallpipeand
Quadra-FireOutsideAirKitinmobilehomes.Single
wallpipeisapprovedforresidentialinstallationsonly.
Air Clearance to Pipe:
Thisappliancewastestedwithstandard76mm
Listedpelletclearancepipetocombustibles.
PelletpipemanufacturesListedreduceclearance
pipemaybeuseforreduceclearancefrom76mm
airclearancetonolessthan25mmairclearanceto
combustiblesforapprovedListedpelletpipe.
Followstovepipemanufactureslistedairclearances
tocombustiblesandinstallationinstructionsforall
reducedairclearancesinstallations.
Thestovemustbeconnectedtoauepipe
conformingtocurrentstandardsUNI7129-7131
9615.
D. Vertical into Existing Chimney
(SHOWN ON A SANTA FE)
C. Through The Wall & Vertical - External
(SHOWN ON A SANTA FE)
Firestop
Flashing
Rain Cap
152mm
Minimum
Non-combustible Hearth Pad
76mm Minimum
Cleanout Cover
305mm Minimum
Ceiling Support
152mm)Flue
Connector
Connector Adapter
76mm-152mm
Top Vent Kit
Non-combustible Hearth Pad
Clean-out Cover
Tee
Wall Thimble
Support
Bracket
every 1.5m
610mm
Minimum
Rain Cap
Flashing
51mm minimum
152mm
Minimum
Figure 28.3
Figure 28.2
Firestop
Flashing
Rain Cap
152mm
Min.
Non-combustible Hearth Pad
76mm Min.
305mm
Minimum
76mm-76mm)
Top Vent Kit
Clean-out Cover
on other side
B. Vertical - Interior - Typical Installation
(SHOWN ON A SANTA FE)
Figure 28.1
PREFERRED METHOD #1
PREFERRED METHOD #2