Rangemaster GLX390 Ventilation Hood User Manual


 
EN
1
2
12
Activated charcoal filter (Recirculation version)
The filter is not washable and cannot be regenerated. It must be replaced when led S1 flashes
or at least every 4 months. The alarm signal will only light up when the extractor motor is
switched on.
Alarm signal activation
• In Recirculation version Hoods, the Filter saturation alarm can be enabled on installation or
at a later date. Turn the Lights and the suction Motor off.
• Disconnect the Hood using the Main switch or the double-pole switch on the mains power
supply.
Restore the connection by pressing and holding T1.
Release the button. All five LEDs are turned on.
Within 3 seconds press T1 until LEDs T1 and T4 flash in confirmation:
- LED flashes twice - Activated charcoal filter saturation alarm ENABLED.
- LED flashes once - Activated charcoal filter saturation alarm DISABLED.
REPLACING THE ACTIVATED CHARCOAL FILTER
Alarm signal reset
Switch off the lights and extractor motor.
• Press button T3 for at least 3 seconds, until the leds start to
flash.
Replacing the Filter
Remove the metal grease filters
Remove the saturated activated carbon filters as shown (A).
Fit the new filters (B).
Replace the metal grease filters.
A
B
Lighting
LIGHT REPLACEMENT
20 W halogen light.
Remove the light cover by unfastening the screws that hold it.
Extract the lamp from the Support.
• Replace with another of the same type, making sure that the
two pins are properly inserted in the lamp holder socket holes.
Replace the light cover.