USE
Control Panel
The hood can be switched on pushing directly onto the requested speed without firstly having
to select 0/1 button.
KEY LED FUNCTIONS
L 0/1 Light Turns lighting on and off.
T1 0/1 Motor on First speed.
When pressed for about 1 seconds the motor
is switched off.
Flashing 24h Changeover
This is enabled by pressing and holding
the button for approximately 5".It al-
lows a suction level of 100 m3/h with a
noise level of just 28dB(A).Can be en-
abled at any speed, even with the hood
turned off.To disable, press and hold
the button for approximately 5".
T2 Speed on Second speed.
Flashing Delay (30')
Press the button for approximately 2" to enable auto-
matic shutdown with a 30' delay. Suitable to complete
elimination of any residual smells. Can be enabled at
any speed and is disabled by pressing the button T1
briefly.
T3 Speed on Third speed.
T4 Speed Fixed Max. speed
Flashing Intensive speed.
Suitable for the strongest cooking vapours and odours.
The function becomes active when the button is
pushed for about 2 seconds. After 10 minutes of func-
tioning it turns off automatically. This function can be
interrupted by means of pressing any of the buttons.
S1 Led Fixed Indicates that the Metal grease filters saturation alarm
has been triggered, and the filters need to be washed.
The alarm is triggered after 100 working hours. (Re-
set; check the Maintenance-paragraph)
Flashing indicates that the activated charcoal odour filter
saturation alarm has been triggered, and the filter has
to be replaced; the metal grease filters must also be
washed. The activated charcoal odour filter is
triggered after 200 working hours. (Activation and
Reset; check the Maintenance-paragraph)
L
S1
T1
T2
T3
T4