Rangemaster RG60 Cooktop User Manual


 
13
8. Technical Data
The hob is an independent Class 3 built-in unit.
This hob is category II
2H3+
It is supplied set for group H natural gas. A conversion kit from NG to LP gas is packed with the hob.
INSTALLER: Please leave these instructions with the user.
DATA BADGE LOCATION: Base of the hob.
COUNTRY OF DESTINATION: GB/IE
Gas Electric
Natural Gas 20mbar 220 – 240V 50Hz
Butane 29mbar
Propane 37mbar
(See appliance data badge for test pressures)
Dimensions
Overall height
Above worktop 50mm Below worktop 50mm
Overall width
620mm; see ‘Positioning of Cooker’
Overall depth
520mm
Space for fixing
See ‘Positioning of Cooker’
Minimum space above hotplate
650mm
Connections
Gas Electric
Rp ½ at rear right-hand side 220 – 240V 50Hz
Ratings
Natural Gas L.P. Gas
Hotplate
Injector Injector
Large Burners 3.0kW 129 3.0kW (218g/h) 87
Medium Burners 1.75kW 101 1.75kW (124g/h) 66
Small Burner 1.0kW 77 1.0kW (73g/h) 50
Gas burner inputs based on Gross Calorific Value
DocNo.101-0001 - Technical data RG60 gas