Raypak D2 Ventilation Hood User Manual


 
9
LEFT SIDE
The D-2 Power Vent assembly includes a wire harness, shown in Fig. 6 below, which provides quick connec-
tions with the respective controls in the heater control box. The harness is of sufficient length to fit the appliance
for which it is sized.
Reference the wiring diagram supplied with each appliance for actual connections.
Fig. 5: Through the Wall Vent
PRESSURE
SWITCH
GAS
VALVE
RELAY
Y/BK
Y/BK
V/BK
V/W
Y/BK V/BK
V/BK
V/W
Fig. 6: D-2 Power Vent Wire Harness