-9-
L20038WT
For all warranty, parts and service needs call 866-365-5339.
REGAL WARE, INC., 1675 REIGLE DRIVE, KEWASKUM, WI 53040
Printed in USA ©2005 Regal Ware, Inc.
TROUBLESHOOTING GUIDE
Problem Possible Cause Solution
AquaVié
™
water The mineral dispenser Replace the mineral dispenser.
has an unusual taste. is contaminated. See page 3.
The water bottle is in Clean the water bottle.
need of cleaning. See page 3.
The boiling chamber Do not overfill the boiling
has been over-filled. chamber. Fill to bottom of
the four tabs at the base of
the boiling chamber’s fill
opening. See #4 on page 4.
AquaVié
™
unit The boiling chamber is not Push the boiling chamber into
is leaking. properly installed. the AquaVié
™
chassis so that
both the boiling chamber and
the electrical connection are
tightly joined. See page 5.
The o-ring is damaged or If damaged, replace o-ring.
missing from the baffle. Make sure the o-ring is
properly placed on the baffle,
fitting in the circular groove.
See page 5.
The flat gasket between Replace gasket.
the boiling chamber
spout and baffle is
missing or damaged.