Samsung CM1029B Microwave Oven User Manual


 
15
Double Quantity Pad Programming
1 Hold down Stop/Cancel and then press DOUBLE QUANTITY pad. Hold
together for 2 seconds.
2 Select desired program code by using NUMBER pads.
3 Press NUMBER pads to set the magnification factor within the range from
1.00 to 9.99.
Default factor is 1.65 preset from the manufacturer for increasing the
cooking time.
Make sure that you set a correct factor between 1.00 and 9.99 for
each memory code number.
4 Press Start pad.
5 Press Stop/Cancel pad to exit the programming mode.
Though you can successfully set a double quantity factor whose
setting might result in excess of the maximum time allowed for each
power level, the oven does not operate exceeding the maximum
time.
Double Quantity Factor Editing
Feature Key Entry Display Remark
1 Hold down Stop/Cancel and then Hold down for 2 sec.
Double Quantity pad.
2 Select desired memory If you press pad 1, default value shows
number in the display window after 1sec.
3 Input desired factor value 1.00 ~ 9.99 available
by pressing NUMBER pad. (Change the factor if required.)
4 Start/20sec.+ Reach completion
If you want to continue to edit new memory number,
follow the above procedures (2~4)
5 Stop/Cancel (Mode cancel) This exits the editing mode.
Double Quantity
Factor Edit
CM1029B-2 6/14/00 10:24 AM Page 15