Scotsman Ice CU2026 Ice Maker User Manual


 
What to do before calling for service
Reasons the machine might shut itself off:
Lack of water.
Freeze cycle takes too long.
Harvest cycle takes too long.
High discharge temperature.
Controller self test failure.
Check the following:
1. Has the water supply to the ice machine or
building been shut off? If yes, the ice machine will
automatically restart within 25 minutes after water
begins to flow to it.
2. Has power been shut off to the ice machine? If
yes, the ice machine will automatically restart when
power is restored.
3. Has someone shut the water off to a water
cooled unit? If yes, after the water supply has been
restored the ice machine may need to be manually
reset.
4. Is the curtain open because some ice is stuck
under it? If so, remove the ice and the machine
should start in a few minutes.
Note: Curtain can be removed & replaced anytime
the machine is in a standby mode or when it is in a
freeze cycle. However, removal of the curtain
during freeze will result in water flowing into the
bin. Removal of the curtain during harvest
terminates harvest at that point and, if left off, will
result in the machine shutting off.
To Manually Reset the machine.
Push and release the Off button.
Push and release the On button.
To Shut the Machine Off:
Move the On Off switch to the Off position.
or, at the controller
Push and hold the Off button for 3 seconds or until
the machine stops.
May 2008
Page 16
CU1526, CU2026, CU3030
User Manual
Manual
Harvest
Clean
Code
Display
Component Operation Indicator Lights
Code Description
.... ......FreezeCycle
flashes....FreezeCycleisPending
.... ......HarvestCycle
flashes....ManualHarvest
.... ......BinisFull
.... ......Clean Cycle
.... ......BoardLocked
.... ......TestMode
.... ......Off
.... ......SelfTestFailed
flashes....MaxFreeze-Retrying
..... ......MaxFreezeTimeShutDown
flashes....MaxHarvest-Retrying
.... ......MaxHarvestTimeShutDown
.... ......SlowWaterFill
.... ......High Discharge Temp
.... ......SumpTempSensorFailure
.... ......DischargeTempSensorFailure
flashes...ShortFreeze-Retrying
Short Freeze - Thin ice
- Unit Remotely
Locked Out - Contact Leasing Company
F
F
H
H
b
C
L
d
O
E
1
1
2
2
3
4
5
7
8
8............
All 4 Upper Lights Flashing
Control Operation - See Manual
Water Light On
De-Scale Light On
Flush Setting
Test Mode
Recall Diagnostic Codes
Reset from Code 1, 2, 4 or 8
- Restore water supply to
machine.
- Clean and sanitize
machine.
- To Change: Depress Off
for 3 seconds. Press On to select purge
(1-5) setting orA forAutomatic.
- Depress Off for 3 seconds,
then depress Clean for 3 seconds.
- Depress Off
for 3 seconds. Press Harvest repeatedly
to go from most recent to oldest of 10.
- Depress
Off then Depress On.
Technician Section
02-4302-01
On Off
Power
Status
De-scaleWater
Sanitize