Scotsman Ice MDT5N40 Ice Maker User Manual


 
MAINTENANCE AND CLEANING
1. Air Cooled Models: Check the air cooled
condenser for lint, dirt or grease build-up. Clean
with vacuum or soft brush until light can be seen
thru the fins.
2. The ice machine senses water level by a probe
located in the water reservoir. At least twice a year,
the probe should be removed from the reservoir,
and the tip wiped clean of mineral build-up.
3. The bin control uses devices that sense light,
therefore they must be kept clean enough so that
they can “see”. At least twice a year, remove the
bin control sensors from the grommets in the ice
chute, and wipe them clean.
4. The bearing in the breaker should also be
checked at least two times per year.
A. Check the bearing by:
·
removing the ice chute cover
·
unscrewing the ice sweep
·
removing the water shed
·
unscrewing the breaker cover.
·
unscrewing the auger stud
Inspect the assembly, looking for wear.
See Removal and Replacement to replace bearing
or seals. Reverse to reassemble.
5. Check and tighten all bolts and screws.
MDT5N25 & MDT5N40
May 2001
Page 19
CLEAN WATER
SENSOR PROBE
CAUTION
THE TIP IS
MADE OF GLASS
Slide UP To
Remove
Reservoir
ICE SWEEP
BIN CONTROL
SENSOR
BIN TOP
BIN CONTROL
SENSOR
Moving Parts Hazard.
Disconnect electrical
power to the icemaker -
dispenser before
beginning.