Sharp AC880 Refrigerator User Manual


 
Page 6
WEIGHT= XX.X LB
AUTOMATIC
?
#
>
WEIGHT= XX.X LB
RECYCLE
?
#
ENTER
RECYCLE HOLD
TIME XX MIN
#
>< ENTER
CHECK HOSES
START
?
#
ENTER
WEIGHT= XX.X LB
COMPRESSOR ON
WEIGHT= XX.X LB
COMPRESSOR OFF
AMOUNT RECYCLED=
XX.X LB
#
ENTER
DRAIN RECOVERED
OIL NOW!
#
ENTER
*
HIGH PRESSURE
SEE MANUAL
**
CYLINDER FULL
GO TO CHARGE
#
RECOVER/RECYCLE
1. Set up the AC880 and turn the Main Power Switch ON.
2. Attach the Red and Blue Hoses to the A/C System per the vehicle
manufacturer's instructions, open the Red and Blue Hose Valves.
3. Using the Keypad, press the “Up Arrow” key one time to display “WEIGHT=
XX.X LB” “RECYCLE?
#” and press the ENTER key. The Display will read
“RECYCLE HOLD” “TIME XX MIN
#”.
The Recycle Hold Time is the amount of time that the AC880 waits for “out-
gassing” or for the pressure in the A/C System to rise enough to automatically
restart the recovery process. The minimum value is two minutes. The value
entered is stored in memory and displays as the default value the next time the
procedure is used.
4. Press the “Up Arrow” key to change the value of the field. Press the “Right
Arrow” key to change to a different field. Press the ENTER key to accept the
value. The Display will then read “CHECK HOSES” “START?
#”.
5. Press the ENTER key to start recovering and recycling with the AC880.
The Display will read the “WEIGHT= XX.X LB” “COMPRESSOR ON”. The
AC880 will recover and recycle refrigerant from the A/C System and
automatically cycle OFF when a vacuum is sensed. This vacuum level can be
seen on the Low Pressure Gauge. The Display will read “WEIGHT= XX.X LB”
“COMPRESSOR OFF”
A small quantity of refrigerant will probably remain in the A/C System as
observed by an increasing pressure on the Low Pressure Gauge. The AC880
will automatically cycle ON to continue recovering refrigerant if pressure rises
to a preset level. This automatic cycling will repeat, resetting the Recycle Hold
Timer each time. When the AC880 remains OFF for the duration of the Recycle
Hold Timer value entered in Step 4 the Display will read “AMOUNT
RECYCLED=” “XX.X LB
#” from the A/C System and the Attention Light will turn
ON.
6. Close the Red and Blue Hose Valves and disconnect the hoses from the A/C
System.
7. Press the ENTER key. The Display will read “DRAIN RECOVERED OIL NOW!”.
Drain any recovered oil using the Drain Recovered Oil procedure on Page 7.
8. Press the ENTER key to return to the Main Menu.
* This screen will display if there is an internal fault. Turn the AC880 Main
Power Switch OFF. Contact RTI Technical Support.
** This screen will display when the Charging Cylinder fills to capacity,
approximately 17.5 lbs (8 Kg.) If this occurs, the Weight can be lowered
using the Charge procedure on Page 9 before the AC880 can be used to
recover more refrigerant. Press the ENTER key to return to the Main Menu.