Installation
WARNING!
Any electrical and/or plumbing work required to
install this appliance should be carried out by a
qualified electrician and/or plumber or
competent person.
WARNING!
This dishwasher may be fed with either hot
(max. 60°) or cold water. Nevertheless we
recommend connection to a cold water supply.
When the dishwasher is likely to be connected
to a solar hot water system, drip heater, or any
other supply where temperatures in excess of
60° are anticipated, a water temperature
tempering valve should be installed. A pressure
reducing valve must be fitted if the hot water
supply pressure can exceed 350 kPa or the
cold supply pressure can exceed 800 kPa.
WARNING!
Always use a new hose-set when connecting
the appliance to the water mains. An old hose-
set must not be reused. The inlet hose should
be inspected every 12 months for deterioration
and replaced if necessary.
Water connection
CAUTION!
If the machine is connected to new pipes or pipes which have not been used for a long time, you
should run the water for a few minutes before connecting the inlet hose.
Inlet hose
Connect the inlet hose to a water tap with an
external thread of 3/4” BSP.
The inlet hose can be turned either to the left or the
right to suit the installation by means of the locknut.
The locknut must be correctly fitted to avoid water
leaks.
Drain hose
- Connect drain hose to the sink. Secure it with the
supplied hose clamp.
- Required height: 30 to 100 cm above bottom of
the dishwasher.
- If you use a drain hose extension the total length
should not be longer than 4 metres. Likewise the
internal diameter of the couplings used for
connections to the waste outlet must be no
smaller than the diameter of the hose provided.