Smeg B72MFX5 Range User Manual


 
Instructions for the installer
21
For operation on 380-415 V 3N
: use an H05RR-F or H05V2V2-F type
five-core cable (5 x 1.5 mm
2
).
For operation on 380-415 V 2N
: use an H05RR-F or H05V2V2-F type
four-core cable (4 x 1.5 mm
2
).
For operation on 220-240 V
: use an H05RR-F or H05V2V2-F type
three-core cable (3 x 2.5 mm
2
).
The cable end to be connected to the appliance must be provided with an
earth wire (yellow-green) at least 20 mm longer.
The manufacturer declines all responsibility for damage to persons or things caused by non-
observance of the above prescriptions or by interference with any part of the appliance.
14.4 Installation of the appliance
It is the law that all gas appliances are installed by competent persons. Corgi gas installers are
approved to work to safe and satisfactory standards. All gas installation, servicing and repair work
must be in accordance with the gas safety regulations 1984 (installation and use) as amended 1990.
This appliance may be installed next to a wall which is higher than the appliance as shown in the
diagram showing the correct installation conditions. Any wall cupboards or shelves must be at a
distance of at least 750 m above the work surface.