Instructions for the installer
81
4.2 Burner and nozzle characteristics table (60 cm model);
Burner
Rated heating
capacity (kW)
LIQUID GAS – G30/G31 28/37 mbar
Nozzle
diameter 1/
100 mm
By-pass
1/100
mm
Reduced
capacity
(W)
Capacity
g/h G30
Capacity
g/h G31
Auxiliary 1.0 50 30 400 73 71
Semi rapid 1.8 65 33 500 127 125
Ultra-rapid 4.0 100 65 1600 290 286
Oven 3.2 87 50 900 233 229
Burner
Rated heating
capacity (kW)
LIQUID GAS – G30/G31 28/37 mbar
Burner
Rated heating
capacity
(kW)
TOWN GAS – G110 8 mbar
Nozzle
diameter
1/100 mm
Reduced
capacity
(W)
Auxiliary 1.0 145 (/8) 400
Semi rapid 1.8 185 (/2) 500
Triple crown 4.0 350 (/13) 1200
Oven 3.2 270 900
The nozzles and data concerning TOWN GAS are available at the Authorised Service Centres.
Burner
Rated heating
capacity
(kW)
NATURAL GAS – G20/G25 20/25 mbar
Nozzle
diameter
1/100 mm
Reduced
capacity
(W)
Auxiliary 1.0 72 (X) 400
Semi rapid 1.8 97 (Z) 500
Ultra-rapid 4.0 135 (K) 1600
Oven 3.2 130 900