Smeg C6GVXI Range User Manual


 
Instructions for the installer
80
4. ADAPTATION TO DIFFERENT TYPES OF GAS
Before carrying out the following operations, disconnect the appliance from the electricity supply.
The appliance is preset for natural gas G20 (2H) at a pressure of 20 mbar. In the case of operation with
other types of gas the burner nozzles must be changed and the minimum flame adjusted on the gas
taps. To change the nozzles, proceed as described in the following paragraphs.
4.1 Replacement of nozzles on the cooking hob
1 Extract the pan stands and remove all the caps and flame-spreader crowns;
2 Unscrew the burner nozzles with a 7 mm socket wrench;
3 Replace the burner nozzles according to the type of gas to be used (see paragraph “4.2 Burner and
nozzle characteristics table (60 cm model);”).
4 Replace the burners in the correct positions.
The nozzles for using town gas (G110 – 8 mbar) are available from authorised service centres.