Smeg CE92GPX Oven User Manual


 
Instructions for the installer
63
17.2 Burner and nozzle characteristics table
Burner
Rated heating
capacity (kW)
LPG – G30/G31 28/37 mbar
Nozzle
diameter 1/
100 mm
By-pass
1/100
mm
Reduced
flowrate
(W)
Flowrate
g/h G30
Flowrate
g/h G31
Auxiliary 1.05 50 30 400 76 75
Semi rapid 1.8 65 33 500 130 128
Rapid 3.0 85 45 800 218 214
Triple crown 4.0 100 65 1600 291 286
Burner
Rated heating
capacity (kW)
NATURAL GAS – G20/G25 20/25 mbar
Nozzle diameter
1/100 mm
Reduced flowrate
(W)
Auxiliary 1.0 72 (X) 400
Semi rapid 1.8 97 (Z) 500
Rapid 3.0 115 (Y) 800
Triple crown 4.0 135 (K) 1600
17.3 Arrangement of the burners on the hob
BURNERS
1. Auxiliary
2. Semi rapid
3. Rapid
4. Triple crown
min. and max. Ø (in cm)
12 - 14
16 - 24
18 - 26
18 - 26