Instructions for the installer
6
2. INSTALLATION OF THE APPLIANCE
It is the law that all gas appliances are installed by authorised persons.
Clearance around the cooker must comply with the requirements of
AS5601.
2.1 Electrical connection
Make sure that the power line voltage matches the specifications
indicated on the rating plate located inside the storage compartment.
This rating plate must never be removed.
On the power line, install a two-pole cut-off device with contact cut-off
distance greater than or equal to 3 mm, located in an easily accessible
position near the unit.
The wire section on the cable must not be less
than 2.5 mm
2
(3 x 2.5 cable), keeping in mind
that the end to be connected to the cooker
must have the ground wire (yellow-green)
longer by at least 20 mm. Use only the special
cables available at our Service Centres.
The manufacturer declines all responsibility for damage to persons
or things caused by non-observance of the above prescriptions or by
interference with any part of the appliance.
Overall dimensions: location of gas and electrical connection points (all
measures in mm).
A 60
B 410
C 60
D 70