Smeg SA9065LPG Cooktop User Manual


 
Instructions for the installer
10
4. ADAPTATION TO DIFFERENT TYPES OF GAS
Before performing any cleaning or maintenance work, disconnect the
appliance from the mains.
The hob of the cooker is adjusted for use with either natural gas at a
pressure of 1.0kPa (SA 9066 – SA 9065) or LPG (propane)
at a pressure
of 2.75 kPa (SA 9066 LPG – SA 9065 LPG). If used with other types of
gas, you have to replace the nozzles, then adjust the minimum flame on
the gas taps. For nozzle replacement and burner adjustment operate as
described in the following paragraph.
4.1 Replacement of nozzles on the hob
This operation requires no primary air regulation.
1. Extract the grids and remove all the caps and flame-spreader
crowns;
2. unscrew the burner nozzles with a 7 mm socket wrench;
3. replace the nozzles according to the type of gas to be used and the
description in paragraph "
3.2 Burner and nozzle characteristics
table".
4. Replace the burners in the correct position.