Instructions for the installer
24
13. INSTALLATION
13.1 Technical information
Oven type See rating plate
Electrical connections 230-240 V ~ 400–415V 3N ~ 50 Hz
Required protection fuse for the oven 30 Amps
OVEN RATING
Ovens Electric
Maximum electrical power 6.1 kW
Oven grilling Electric
Large grilling power 3.0 kW (230 V)
Small grilling power 1.8 kW (230 V)
Ovens lightings 25 W (230 V)
Large oven Small oven
OVEN CAVITY DIMENSIONS
Height (cm) 34 23
Width (cm) 46 46
Depth (cm) 40 40
Internal volume (cm
2
) 62560 42320
13.2 The rating plate
CHECK THAT MAINS VOLTAGE AND POWER CABLE RATINGS ARE AS PER THE INDICATIONS
PROVIDED ON THE LABEL ATTACHED TO THE OVEN DOOR FRAME.
THIS LABEL MUST NEVER BE REMOVED.
Model Serial N°
13.3 Electrical connection
IT IS OBLIGATORY FOR THE ELECTRICAL SYSTEM TO BE GROUNDED ACCORDING TO THE
METHODS REQUIRED BY SAFETY RULES.
WHEN LINKING UP TO MAINS BY PLUG AND SOCKET, MAKE SURE THAT BOTH ARE
COMPATIBLE AND CONNECT BY MEANS OF A POWER CABLE COMPLYING WITH APPLICABLE
REGULATIONS.
THE SOCKET MUST BE ACCESSIBLE AFTER THE APPLIANCE HAS BEEN BUILT IN.
NEVER UNPLUG BY PULLING ON THE CABLE.
IMMEDIATELY AFTER INSTALLATION CARRY OUT A BRIEF INSPECTION TEST OF THE OVEN,
FOLLOWING THE INSTRUCTIONS. SHOULD THE APPLIANCE NOT FUNCTION, DISCONNECT IT
FROM THE SUPPLY AND CALL THE NEAREST TECHNICAL ASSISTANCE CENTRE.
NEVER ATTEMPT TO REPAIR THE APPLIANCE.
IF A PLUG AND SOCKET CONNECTION IS BEING USED MAKE SURE THAT THE PLUG AND
SOCKET ARE COMPATIBLE. AVOID USE OF ADAPTERS AND SHUNTS AS THESE COULD
CAUSE OVERHEATING AND RISK OF BURNS.
IF A FIXED CONNECTION IS BEING USED FIT POWER LINE WITH AN OMNIPOLAR CIRCUIT
BREAKER WITH A CONTACT OPENING GAP EQUAL TO OR GREATER THAN 3 MM IN AN
EASILY ACCESSIBLE POSITION IN PROXIMITY TO THE OVEN.