Spectra Watermakers 150 Water Dispenser User Manual


 
22
Spectra cleaning compound (SC-2 or SC-3) must be mixed with fresh water at a ratio of 1 con-
tainer of compound to 3 gallons (12L) of unchlorinated water to have the proper solution. An av-
erage of two gallons (8L) of water is already present inside a 150 system. This water has to be fig-
ured into the mixture. A Ventura 150 system will use one container of compound,
Note: Procedures are the same for the SC-2 and SC-3 cleaners
Cleaning Procedure:
1. Close the service valve, open the flush valve and run the feed pump for 4 minutes to
flush the system. Stop the pump and close the flush valve.
2. Connect your inlet service hose and the brine discharge service hose. Open the flush valve
and start the pump until you get a gallon (4L) of water in the bucket.
3. Turn the service valve to the service position.
4. Make sure that the pressure relief valve is OPEN (un-pressurized).
5. Mix the cleaning chemical in the bucket.
6. Start the system and circulate the chemical through the system for the required time.
7. Stop the pump, replace the brine discharge hose and start the pump until the bucket is
empty. Stop the pump and rotate the service valve back to the run position. Restart the
pump and run for 20 minutes to flush the chemicals out of the system.
(DO NOT CLOSE the pressure relief valve!)
8. The system should now be restarted to make water, fresh water flushed, or stored.
.
Valves in flush position
Open the pressure relief valve
Valves in service position
Connecting brine discharge hose