Sterilite Point-of-Use Drinking Water System Water Dispenser User Manual


 
12
425 Clair Rd. West
P.O. Box 1719
Guelph, Ontario, Canada N1H 7X4
tel. (519) 763-1032 • Fax (519) 763-5069
1-800-265-7246
email: water@r-can.com • Internet: www.r-can.com
US Patents: 5540848, 5266215, DS 357058
Other Patents Pending
©2001, R-Can Environmental Inc.
REPLACEABLE PARTS LIST
Your Sterilight Point-of-Use treatment system has
very few user-serviceable parts:
Filter Cartridge................... SWM-C1
Filter Cap O-ring................ OR-SWM
Lamp Assembly................. SWM-RL
Quartz Sleeve..................... QS-SWM
PARTS & SERVICE: Contact your Sterilight dealer.
SWM SPECIFICATIONS
Power requirements: SWM1, 115V AC, 20 WATTS
SWM1/2, 220V AC, 20 WATTS
Flow rate: Up to 2 lpm (0.5 gpm)
Minimum inlet pressure: 30 PSIG
Maximum operating pressure: 6.9 bar (100 PSIG)
Filter life: 6 months or 1900 liters (500 gallons)
Lamp life: 10,000+ on/off cycles
Weight: Approximately 2.2 kg. (5 lbs.)
Dimensions: Approximately 150 x 445 mm
(5.9 x 17.5 inches)
Chemical additives: None; (ozone created in unit)
Chemical emissions: None; (ozone reconverted to oxygen
in the lter cartridge element)
ENV IRO NME NTA L INC
Ensuring the Safety of Your Water