installation
STEP 2 & 3 CONNECT TO THE ELEC-
TRICITY SUPPLY
We recommend that the appliance is
connected by a competent person who
is a member of a “Competent Person
Scheme” & who will comply with the
I.E.E. & local regulations.
Important:Ensurethatyourouteall
mains electrical cables well clear of any
adjacent heat source, such as an oven or
grill.
Warning:Thisappliancemustbeearthed.
For 60cm BI appliance:
1.Whereaxedconnectionisused,
a device allowing the appliance to be
isolated on all poles from the mains
supply with a contact opening width of at
least 3mm must be provided.
Use a 13 amp fuse.
2. A type HO5 V V-F cable must be used
as the mains lead. The cross section must
be a minimum of 1.5mm².
3. The mains terminal block is located
at the right hand rear of the top service
panel.
4. Connect the cable to the terminal block
& tighten the cable clamp.
5. Close the terminal box, ensuring the
cover is engaged on the locking tabs.
For 70/90cm appliances:
1. The appliance must be installed using
a double pole control unit of 32 ampere
minimum capacity separation at all poles.
2. Access to the mains terminal is gained
by opening the terminal block cover at
therearoftheappliance(useasmallat
bladedscrewdriver).
3. Connection should be made with
suitabletwin&earthexiblecable,
minimum 4mm² , which is suitable for use
up to 25 amps.
4. First strip the wires, then push the
cable through the cable clamp in the
terminal block cover.
5. Connect the cable to the terminal block
& tighten the cable clamp screw.
6. Close the terminal box, ensuring that
the cover is engaged on the locking tabs.