Sub-Zero 427RG Refrigerator User Manual


 
Position the Unit
R
etract the front leveling legs all the way up to allow the
unit to be moved into position more easily. You will extend
the leveling legs when the unit is in its final position to
reduce the possibility of the unit tipping forward.
Use an appliance dolly to move the wine storage unit near
the rough opening. Position the dolly at the side of the unit
to prevent damage to finished surfaces.
IMPORTANT NOTE: If for any reason the wine storage unit
has been laid on its back or side, you must allow the unit
to stand upright for a minimum of 24 hours before con-
necting power.
Plug the power cord into the grounded electrical outlet.
With power applied to the appliance, check for lighting
and cooling before going any further. Once you are satis-
fied that the unit is operating properly, shut off power to
the electrical outlet at the circuit breaker and proceed.
Pre-level the wine storage unit before moving into
position. This is to allow the unit to engage the anti-tip
bracket properly.
If a home alarm system is to be used with the wine
storage unit, the lead wires should be threaded into the
compressor compartment before you position the unit.
Refer to wiring connections on page 24 for the location of
these lead wires. After the unit is in position, the alarm
wiring can be completed from the front.
Models 427G and 427RG Installation 22
S
lide the unit into position, making sure the anti-tip
bracket is engaged properly. Extend the front leveling legs
down approximately
3
/16" (5) to make additional adjust-
ments easier.
When the wine storage unit is installed, the anti-tip
bracket will be positioned just below the engaging bracket
on the unit. It is not necessary to raise the unit up so that
it locks into the anti-tip bracket, but the unit must be in
alignment with the anti-tip bracket.