28
|
Wolf Customer Care 800.222.7820
Planning Information
DRAWER MICROWAVE
Wolf drawer microwave ovens can be installed in a standard
or ush inset application. The cabinet must be able to sup-
port 125 lbs
(57 kg).
Finish the edges of the opening. They may be visible when
the drawer is open.
For ush inset installations, a minimum
1
/8" (3) reveal is
required on the top and sides and
11
/16" (18) on the bottom.
A sales accessory is required to direct air away from the
unit. Accessories are available through an authorized Wolf
dealer. For local dealer information, visit the nd a show-
room section of our website, wolfappliance.com. To ensure
consistent reveals, each corner of the opening must be
exactly 90°.
TRIM OVERLAP
DRAWER MICROWAVE 24" MODEL 30" MODEL
Top
5
/16" (8)
5
/16" (8)
Bottom
1
/16" (2)
1
/16" (2)
Sides
3
/4" (19) 3
7
/8" (98)
WOLF MICROWAVE OVENS
RANGES / RANGETOPSVENTILATION COOKTOPS OVENS / WARMING DRAWERSOUTDOOR GRILLS
CONVECTION AND STANDARD MICROWAVES
Wolf convection and standard microwave ovens can be
used freestanding or built into cabinetry using accessory
trim to match Wolf L series or E series ovens. Trim kits are
avail able through an authorized Wolf dealer.
For freestanding applications, a minimum 2"
(51) space is
required at the top, rear and sides of the microwave oven for
air circulation.
TRIM OVERLAP
27" E SERIES TRIM CONVECTION STANDARD
Top
1
/4" (6)
9
/16" (14)
Bottom
3
/4" (19)
11
/16" (17)
Sides
13
/16" (21)
13
/16" (21)
30" L / E SERIES TRIM CONVECTION STANDARD
Top
1
/4" (6)
9
/16" (14)
Bottom
3
/4" (19)
11
/16" (17)
Sides 1
3
/16" (30) 1
3
/16" (30)
36" L SERIES TRIM CONVECTION STANDARD
Top
3
/16" (5) NA
Bottom
13
/16" (21) NA
Sides 1
1
/4" (32) NA
ELECTRICAL
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations on
the following pages. The receptacle may also be located
in an adjacent cabinet within reach of the power cord. An
access hole must be provided through the cabinet for the
power cord. A separate circuit, servicing only this appliance
is required. A ground fault circuit interrupter (GFCI) is not
recommended and may cause interruption of operation.
Refer to the illustration below for minimum power cord plug
clearance.
ELECTRICAL REQUIREMENTS
Electrical Supply grounded, 120 VAC, 60 Hz
Service 15 amp dedicated circuit
Receptacle 3-prong grounding-type
Power Cord 4'
(1.2 m)
3"
(76)
MINIMUM CORD
CLEARANCE
Power cord clearance.