Sub-Zero ICB427R Beverage Dispenser User Manual


 
30
MODEL ICB430 INSTALLATION INSTRUCTIONS
Glass
Gasket
11 mm
Diameter
6 mm
Diameter
Illus. 8
Illustration 8 shows how this hole passes
through the door frame. The hole center is on
the small locator groove in the front of the
frame. A 6 mm diameter hole is made in the
front wall of the extrusion and a 11 mm
diameter hole through the rest of the frame.
Sub-Zero allows a 6 mm space to slide the
backing material into place on the door frame.
Requirements for proper fit and appearance
are; 16 mm minimum overall thickness, 3 mm
wide groove between backer portion and
overlay portion of panel, finished inside edge
and 11 kg maximum weight. See the Wine
Storage section of the Sub-Zero Design Guide
for additional panel information.
The wine storage unit door is made with
a sealed double wall tempered glass core.
The drill must not contact this core when
drilling. Be sure the hole is centered on
the small groove in the front of the door
frame and the drill passes squarely
through the frame. If you are inexperi-
enced with drilling, fasten the handle from
the rear of the door panel only.
OVERLAY DOOR PANEL
If your customer has chosen an overlay design
door and grille panel, the unit will be shipped
without handle and hardware. The cabinet
manufacturer or designer will provide handle
hardware at the job site to match the overall
decorating scheme. We recommend larger
D-style pulls. The use of small, one-piece
knobs is not recommended.
The metal frame on the glass door has
numerous mounting holes on each side of the
door. This is to accommodate the Sub-Zero
accessory handles and provide for easy attach-
ment of the handle through the door frame.
If you choose not to use these pre-drilled
mounting holes, you must either drill addi-
tional holes through the metal frame of the
door, or attach the handle through the door
panel only.
If you attach through the door panel only, the
handle must be attached before the door panel
is installed and the handle screws will need to
be set into the rear surface of the door panel.
If you choose to drill through the metal door
frame, this must be done before the handle
holes are located and drilled in the panel.
MODEL
ICB430
PANEL
DESIGN
Additional panel
design information
can be found in
the Sub-Zero
Design Guide.
Check our website
at subzero.com.