16
COMPLETING THE INSTALLATION
DOOR ADJUSTMENT
The doors for Built-In side-by-side models and
t
he upper door on over-and-under models can
be adjusted in threeways: In and out, side to
side tilt, and upand down (exceptover-and-
under models).
Regardlessof the adjustmentbeing made, start
b
y slightly loosening the two upper hinge bolts
on the upperhinge plate using a 13 mmwrench.
R
efer to the firstillustration below.
IN AND OUT ADJUSTMENT
The second illustration below points out the
proper bolt for the inand out door adjustment.
A 4 mm allen wrench is required.
To adjust a left-hinge door, turn the bolt clock-
wise to bring the handle side of the door inward,
and counterclockwise to move the handle side of
the door outward. Reverse the directions fora
right-hinge door.
Upper Hinge Bolts
In and Out
Adjustment
Side to Side
Tilt Adjustment
Door adjustment—upperhinge
bolt
Door adjustments
Door height adjustment
SIDE TO SIDE TILT ADJUSTMENT
T
he second illustration below also points out the
proper bolt for the side to side tilt door adjust-
ment. A 9 mm wrench is required.
For a left-hinge door, turn thebolt clockwise to
raise the handle side of the door up andcounter-
clockwise to tilt the handle side of the door
down. Reverse the directions for a right-hinge
d
oor.
DOOR HEIGHT ADJUSTMENT
A 6 mm allen wrench is required.
For a left-hinge door, turn thebolt clockwise to
raise the door and counterclockwise to lower the
door. Refer to the illustration below. Reverse the
directionsfor a right-hinge door.
90° DOOR STOP
The doors of all Built-inmodels open to 110°.
A
n optional 90° door stop kit is availablethrough
your Sub-Zero dealer.
The 90°door stop will be installed in the top
hinge of thedoor. To install,open the door to
approximately 90°. At the top of thedoor, insert
t
he door stop down between the door hinge and
the door closer arm. Insertthe screw through the
d
oor stop and into the door as shown in the
illustration below.
ANCHOR THE UNIT
After door and side panels have been installed,
t
he unithas been leveled and door adjustment
completed,anchor theBuilt-In unit to the
opening. This will assure a proper fit and a
secure installation.
IMPORTANT NOTE:
Be sure to level and square
t
he unitbefore anchoring it.
To anchor the unit to cabinetry, open the grille,
a
nd install the screws provided through the grille
frame into the cabinetry. There are several hole
locations provided. Check for proper door clear-
ance by fully opening the door. Refer to the illus-
tration below.
Next, drill a screw through the side hole inside
the roller base assembly. There is one on each
side. The screw willneed to go in at an angle in
order to attach properly.
Anchoring Screws
Top anchoring 90° doorstop
AIR PURIFICATION SYSTEM
All Sub-Zero Built-In units, except Model
ICBBI-36F, come with an advanced air purifica-
tion system. A factory installed airpurification
cartridge is locatedinside therefrigeration
section, on the right-handside of the back wall.
For information regarding use and removal of
this cartridge,please refer to the Built-In Refrig-
eration Use & Care Information provided with
the unit.
ACCESSORIES
Optional acces-
soriesare available
through your
Sub-Zero dealer. To
obtainlocal dealer
information,visit
our website,
subzero.com.
If thescrews provided are not suitable for
your application, you mustprovideadequate
screws.
CAUTION
CAUTION
LAMP CONTAINS MERCURY
Manageinaccordance with disposal
laws.