Sub-Zero ICBBI-48S Refrigerator User Manual


 
Plumbing Requirements
For integrated models with an automatic ice maker, the
water supply line should be located through the floor or
back wall, within the shaded area shown in the illustra-
tions. The water supply line should be connected to the
house supply with an easily accessible shut-off valve
between the supply and the unit. Do not use self-piercing
valves. A saddle valve kit (4200880) is avail able through
your authorized Sub-Zero dealer.
IMPORTANT NOTE: It is critical that the water line be
located within the shaded area shown so it does not inter-
fere with installation of the anti-tip bracket.
An in-line filter is required when water conditions have a
high sediment content. The ice maker operates on
constant water pressure between 1.4 bar and 6.9 bar.
IMPORTANT NOTE: In some cases, a reverse osmosis
water filter system may not be able to maintain the
minimum pressure consistently.
Plumbing Requirements
Water Supply Line 6.35 mm OD copper line
Water Pressure 1.4–6.9 bar
Excess Water Line for Connection 686 mm
76 mm
229
mm
19
mm
FLOOR
64 mm
FRONT VIEW
686 mm models.
229
mm
152
mm
TOP VIEW
38
mm
64 mm
BACK
WALL
343 mm
76 mm
FRONT VIEW
1
9
mm
FLOOR
64 mm
914 mm models.
343
mm
TOP VIEW
152
mm
38
mm
64 mm
B
ACK
WALL
Integrated Refrigeration 44